Datacenter Operation Measures Service Green Air IDC

Green Air IDC offers end-to-end data center optimization—diagnosing thermal and energy performance, then delivering energy-saving tuning, planning, design, construction, and after-sales support. Trusted by 100+ global validations.

Schedule Your Demo Today Datacenter Tech

(Patent No. 5306969, Patent No. 5306970, Patent No. 5324363, Patent No. 5421570, Patent No. 5729993, etc.)

IDC Business Operator Needs

(click on image for full view)

Solve thermal problems such as high loading of blade servers and the cloud

Implement energy conservation to comply with laws such as The Revised Rationalization in Energy Use Law

Secured Reliability

One-Stop Service

Datacenter User Needs

Lifecycle-wide data center services

(click on image for full view)

Customized IDC services—from diagnostic assessments to energy-saving tuning—delivered on demand

Our use of advanced thermal cameras ensures targeted measurements and rapid airflow control, keeping assessment periods hassle-free

Comprehensive evaluation technology—including measurement and CFD analysis—enables diagnostics at both construction and operational stages

Understand the advance effects of tuning by simulation
* Computational Fluid Dynamics

Datacenter Timeline
Datacenter Use Cases

Diagnosis

(click on image for full view)

Tailored measurement survey and analysis proposals

Proven diagnostics with 100+ projects in Japan and abroad

As part of our service, we also conduct simulation by CFD analysis, but we also visualize the temperature distribution by converting it to 3D with a thermo camera and a special filter based on actual measurements of the server room environment to make the situation understandable for IT engineers.

By doing this, we can share problem areas with customers and use the results for planning and measures for subsequent solutions.

Datacenter Diagnosis Example
Datacenter Diagnosis Use Case

Tuning & Checking

(click on image for full view)

Tuning

We perform containment (capping), etc. of air flow adjustment, air volume adjustment, cold aisles, and hot aisles with inexpensive materials. We also have a track record of achieving energy-savings of 25% reduction by improving operations, etc. without costly measures.

By supplying the supply air to the servers uniformly, we increase the setting of supplied cold air and improve operational efficiency.

Checking

After tuning, etc. is completed, as a check that must not be forgotten, we recommend that customers check for any potential problems such as when the air conditioner breaks down or when there is a power outage.

Energy-saving temperature adjustments are meaningless if an emergency strikes. That's why we simulate outages—pausing the air conditioning during planned power cuts or generator tests—and monitor the server room's thermal response to ensure you remain protected under all conditions.

An Example Of A Simulation

Datacenter Tuning and Checking Example Simulation

Explore Other Service and Technology Solutions